<LOGO>
FM Transmitter Measurement Report
Created: 2026-03-02 19-42-53
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.30 MHz 5/5, 50 dBuV NOSTALGI
Pilot RDS Phase Difference
6.2 kHz 4.1 kHz 80 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 69 kHz 18985 0,1264
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,7 dBr 5,52 dBr 7,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"NOSTALGI" 6411 10 (Pop M) 1 0 1 7 --:--
RT
"Simon & Garfunkel - Bridge over troubled water "
AF EON
89.7, 90.9, 92.7, 94.3, 98.4, 99.5 MHz -
FM Scope Max at: 69 kHz MIN: 10 kHz % above 76 kHz: 0,1264 Acquired: 2026/03/02 19.41.49 Total samples: 18985 Equivalent time: 0:15:49 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000
FM Scope MAX: 7,1 dBr MIN: 2,7 dBr AVE: 5,52 dBr % above 12,2 dBr: 0,0 Last value: 5,0 dBr (2026/03/02 19.41.49) 19.28 19.30 19.32 19.34 19.36 19.38 19.40 0 2 4 6 8 Pm [dBr]